Brooks Automation
46 260301 Revision A
7 Operation ATR60LF RFID Reader CAN Bus
7.4 Attribute (ECID and SVID) Values Product Manual
ASCII_T3
(ASCII only)
Inter-block timeout
2 - 120 * 1 s (2 - 120 s)
Default: 45 (45 s)
BAUDRATE Specifies the communication baud rate
1 - 4,800
2 - 9,600
3 - 19,200
4 - 28,800
5 - 57,600
Default: 9,600
CarrierIDLength CarrierIDLength ranges from 1 to CID_MAX_LENGTH.
Default: 16
CarrierIDOffset CarrierIDOffset ranges from 0 to CID_MAX_LENGTH-1.
CarrierIDOffset + CarrierIDLength cannot be larger than the length of the
CID field (CID_MAX_LENGTH).
Default: 0
CHECKSUM (ASCII
only)
Checksum enabled or disabled.
EN = Enabled
DI = Disabled
Default: DI
CID_DISPLAY OFF - returns MID without padding information and allows non-printable
characters in MID while reading even if CID_NP_ASCII = OFF.
ON - returns MID along with padding information
Default: ON