EasyManua.ls Logo

Brooks RFP6 - 5.2.2 Ancillary Function Tests; 5.3 Panel Testing Procedures; 5.3.2 Alarm Test Procedure

Default Icon
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BROOKS AUSTRALIA RFP6 Installer ISSUE 4
28
5.2.2 Ancillary Functions
'PANIC' - Disconnect the 'Panic' input and using a multi-meter set to ohms check for
an Open Circuit across the field wiring. Operate the 'Panic' device and ensure meter
reads short circuit, reset the panic device if necessary and ensure it again reads open
circuit. Reconnect the wiring.
'12 Volt' - Disconnect the field wiring and using a multi-meter set to ohms ensure that
there is no short circuit between the field wiring inputs. (The exact field resistance will
be a function of the device connected i.e., Fire Bell - 150 ohms). Reconnect the
wiring.
5.3 Panel Testing
5.3.1 General
Connect Battery Leads: Red - Positive
Black – Negative
Connect Power and Switch ON the Mains. All zone fault LEDs will illuminate
for a few seconds and sounder will sound
Power ‘on’ LED should light green, no other facility or indicator should
function
5.3.2 Alarm Test
Ensure control panel is in the "Normal" condition, keyswitch in the "ON"
position. Power on - Green LED.
Turn the key switch to place the panel in 'FIRE' mode
Check:
1. No Alarm LED illuminates
2. All smoke alarms sound
3. Ancillary Outputs activate. Check operation of all ancillary
equipment.
Switch to "FIRE/LOCATE" by pressing the Locate switch to 'ON' while key is
still in Fire Mode. Amber LED illuminates. All alarms are silenced.
Return Key switch to 'ON'. Turn Locate switch off. (i.e. amber LED
extinguishes).
NOTE: Some ancillary equipment may be latching or simply require re-setting. This
should be done before proceeding.

Table of Contents

Related product manuals