BROOKS AUSTRALIA RFP6 Installer ISSUE 4
25
4. Installation
The Residential Panel is factory pre-wired and fully tested before delivery. After
receipt of the panel, the unit should be carefully checked for any possible mechanical
damage during transportation. Report any damage to your supplier immediately.
4.1 Surface Mounting Instructions
Step 1. Locate the position where the panel is to be sited.
Step 2. Mark the position of the two mounting holes (160mm apart) and the
cable cut-outs, 5 knockouts available between the two mounting
holes. Note that Power and ELV cables are to be kept segregated.
Step 3. Select the appropriate mounting hardware and prepare the two
mounting holes.
Step 4. Fix the top two points, leaving approximately 6 mm of the protrusion
from the wall. Mount the Panel and secure all mounting hardware.
4.2 Recommended Mounting Hardware
Masonry
Drill - 6.5 mm
Rawlplug - Green
Fastener - 8 gauge x 25 mm zinc plated self-tapping screws
Plaster Board
Drill - 8 mm
Fastener - Hollow wall anchors type SWA416 or equivalent
Solid Timber
Drill - 3 mm
Fastener - 8 gauge x 25 mm zinc plated self-tapping screws
4.3 Cable Terminations
4.3.1 AC Power
The 240V AC input is terminated on the mains isolate switch and earth stud provided
on the rear inside of the enclosure.
NOTE: This panel can be wired to the AC Power Input or connected to a
GPO via a 3-core flex cable, whichever is the more appropriate
.