11. STANDARD ADJUSTMENTS
BAS-342G PS
56
11-2. Adjusting arm thread guide R
The standard position of arm thread guide R (1) is when the
screw (2) is aligned with the index mark.
Loosen the screw (2) and move arm thread guide R (1) to
adjust.
* When sewing heavy material, move arm thread guide R
(1) to the left. (The thread take-up amount will become
greater.)
* When sewing light material, move arm thread guide R
(1) to the right. (The thread take-up amount will become
less.)
11-3. Adjusting the needle bar height
Turn the machine pulley to move the needle bar to the lowest position. Then remove the rubber plug (2), loosen the screw
(3) and then move the needle bar up or down to adjust so that the second reference line from the bottom of the needle bar
(reference line A) is aligned with the lower edge of the needle bar bush (1).
* If using a DP X 5 needle, use the highest reference line (reference line a).
2552Q
2582B
More thread Less thread
Index mark
2588B