EasyManua.ls Logo

BRP Evinrude E-Tec 15 HP - Page 87

BRP Evinrude E-Tec 15 HP
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
85
PREDELIVERY
RUNNING CHECKS
5
Emergency Stop / Key Switch
Check emerg ency stop funct ion. With outbo ard
running at IDLE, pu ll sa fety lanya rd from emer-
gency stop switch . Outb oard must stop immed i-
ately.
Remote Control Operation
Make sure th at contro l can be easily move d into
all gear an d throttle settings. Do not shift remote
control when outboard is not running.
Start-In-Gear Prevention
Start outboard and shift to FORWARD.
Turn outboard OFF while control is in FORWARD.
Try to rest art the outboard. Outboar d sho uld not
start.
Shift back to NEUTRAL and restart outboard.
Shift to REVERSE. Turn outboard OFF while con-
trol is in REVERSE.
Try to rest art the outboard. Outboar d sho uld not
start.
Tachometer Pulse Setting
(SystemCheck)
Confirm accuracy of tachometer reading.
Adjust dial on back of t achometer to required
setting (the outboard should not be running).
I-Command Set up
Complete b asic se t up of I-Command g auges.
Configure engine and fuel tank, set fuel tank
capacity etc. Refer to I-Command User’s Guide.
Water Pump Overboard Indicator
A st eady stre am of water should flo w f rom th e
overboard indicator.
Operating Temperature
An o utboard run a t idle speed should a chieve a
temperature based on the engine’ s thermost atic
control. In general, the p owerhead temperatu re
should reach at least 104°F (40 °C) after five min-
utes of idling. Check that the powerhead reaches
idle temperature.
Idle Speed
Make sure th e outboard idles within the specifie d
idle RPM ran ge. If the outboard is run on a flush-
ing device, the idle speed a nd quality may not be
representative of actual in water use.
Break-In
Evinrude E-T EC o utboards req uire no brea k in.
When the outboard is delivered, re fer the cus-
tomer to the Oiling System information in th e
Operators Guide.
A WARNING
Make certain that the starter will not oper-
ate when the outboard is in gear. The start-
in-gear prevention feature is required by
the United States Coast Guard to help pre-
vent personal injuries.
Outboard Model Tachometer Setting
15–300 HP 6 Pulse or 12 Pole
1. Water pump overboard indicator 008469B
1

Table of Contents