73
Installation
Tighten all connections securely and coat the
installation with Triple-Guard grease.
Service
Before servicing the battery or the outboard,
remove both battery cables from the battery,
battery negative (–) cable first. Keep metal
objects from contacting either battery post.
Water Pressure
An optional water pressure gauge is recom-
mended to monitor cooling system pressures.
Noticing changes in water pressure can help
prevent engine overheating. The water pres-
sure gauge must be connected at the correct
point to ensure the most accurate pressure
readings. Follow the installation instructions
included with the water pressure gauge.
1. Main cable
2. Starwasher
3. Accessory wires
DR6496
DR5104
WARNING
Battery electrolyte is acidic — handle
with care. If electrolyte contacts any part
of the body, immediately flush with water
and seek medical attention.
Do not use a booster battery and jumper
cables to start the outboard. Gasoline
fumes can cause explosion and fire,
resulting in property damage, personal
injury or death.
NOTICE
Service electrical components only while
the outboard is NOT running. Be careful
when identifying positive and negative
battery cables and posts.
1. Water pressure port (behind fuel filter)
2. Fuel filter