Page #153 background imageLoading...
Page #153 background image
BRP-Rotax
MAINTENANCE MANUAL LINE
General note
m WARNING
Risk of burns and scalds. Hot engine parts.
Always allow engine to cool down to ambient temperature before starting work.
m WARNING
Risk of electric shock!
Ignition “OFF” and system grounded! Disconnect negative terminal of battery.
NOTE
It is advisable to check the oil level prior to an oil change as it informs about oil
consumption.
See Chapter 12-10-00 section Oil level check/Replenish.
Observe
NOTICE
Observe the following to prevent possible unintentional voiding of the oil system
and damage to the valve drive:
Draining the suction lines, oil cooler and return line is not necessary and must be
avoided, as it results in air entering the oil system.
See Chapter 12-20-00 section Purging the oil system.
Replacement of the oil filter and the oil change should be effected quickly and without
interruption to prevent a draining of the oil system and the hydraulic tappets.
Effectivity: 916 i A / C24
Edition 0/Rev. 1
12–20–00
Page 29
December 01 2023

Other manuals for BRP ROTAX 916 i A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BRP ROTAX 916 i A Series and is the answer not in the manual?

BRP ROTAX 916 i A Series Specifications

General IconGeneral
BrandBRP
ModelROTAX 916 i A Series
CategoryEngine
LanguageEnglish

Related product manuals