EasyManua.ls Logo

BRP ROTAX 916 i A Series - Wastegate and PCV Check; Engine Instruments Check - Wastegate;PCV; Set Throttle Valve to WOT; Deactivate ECU Lane A for Wastegate Check

BRP ROTAX 916 i A Series
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BRP-Rotax
MAINTENANCE MANUAL LINE
Points of Inspection
Interval Operating hours Chapter
Reference
Signa-
ture
* no periodic maintenance (re-
quirement after the first 25 hours
of operation)
25* 50 100 200 400 600 1000
3) Spark plug
Check that spark plug connectors fit
tightly on the spark plugs. Minimum
pull-off force is 30 N (7 lb).
X 12–20–00
Inspection of
spark plugs
Remove all spark plugs and check
for spark plug defects (deposits,
melting,...). Check if GENUINE-RO-
TAX®- spark plugs are used.
X X 12–20–00
Remove the
spark plugs
Replacing spark plugs.
(2
use of leaded fuel (AVGAS) more
than 30% of operation
X
(2
X 12–20–00
Installation
of spark
plug
4) Inspecting the magnetic plug
Check the magnetic plug.
X X 12–20–00
Inspecting
the mag-
netic plug
5) Inspecting the oil filter
Remove oil filter from engine. Cut
old filter without producing any metal
chips and inspect following compo-
nents for wear and/or missing
material.
Filter mat:
Findings:
____________________________-
________
X
(3
X 12–20–00
Inspection of
the oil filter
components
(3
use of leaded fuel more than 30% of operation
6) Visual inspection of the engine
General visual inspection of the en-
gine for damage or abnormalities.
Check cooling air duct and cooling
fins of the cylinders for obstruction,
cracks, wear and good condition.
Take note of changes caused by
temperature influence.
X X 12–20–00
Visual
inspection
Effectivity: 916 i A / C24
Edition 0/Rev. 1
05–20–00
Page 9
December 01 2023

Other manuals for BRP ROTAX 916 i A Series

Related product manuals