EasyManuals Logo

BRP ROTAX 916 i A Series Maintenance Manual

BRP ROTAX 916 i A Series
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
BRP-Rotax
MAINTENANCE MANUAL LINE
Points of Inspection
Interval Operating hours Chapter
Reference
Signa-
ture
* no periodic maintenance (re-
quirement after the first 25 hours
of operation)
25* 50 100 200 400 600 1000
7) Oil change
Drain oil from oil tank.
X X
(4
X 12–20–00
Oil change
Check the oil tank and clean the oil
tank if contaminated.
X
(4
X 12–20–00
Oil change,
Cleaning the
oil tank
Refill oil tank with approx. 3 liters of
oil. For oil quality, see Operators
Manual (OM) latest edition.
X X
(4
X 12–20–00
Purging the
oil system
Inspect and clean screen in turbo oil
sump.
X
(4
X 12–20–00
Turbo sump
screen
Install new oil filter
X X
(4
X 12–20–00
Oil filter
change
(4
use of leaded fuel (AVGAS) more than 30% of operation
8) Fuel system
Inspect the fuel system on the en-
gine side for leaks.
X 12–20–00
Fuel system
Inspect the fuel system for damages.
X
9) Engine management
Check the ECU and its mountings.
X 12–20–00
Checking
ECU
In case of faults or warnings read out
the ECU fault memory (fault and da-
ta logs).
X X 12–20–00
Read out
the ECU da-
ta memory
10) FUSE BOX
Check the FUSE BOX and its
mounting.
X
Visual inspection of the fuses.
X X
Effectivity: 916 i A / C24
Edition 0/Rev. 1
05–20–00
Page 11
December 01 2023

Other manuals for BRP ROTAX 916 i A Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BRP ROTAX 916 i A Series and is the answer not in the manual?

BRP ROTAX 916 i A Series Specifications

General IconGeneral
BrandBRP
ModelROTAX 916 i A Series
CategoryEngine
LanguageEnglish

Related product manuals