EasyManua.ls Logo

BRP ROTAX 916 i A Series - Final Checks and Fuel Pump Verification; Engine Instruments Check - Lane A;B; Activate ECU Lane B for Wastegate Check; Warning Indicator B Check - Wastegate;PCV

BRP ROTAX 916 i A Series
182 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BRP-Rotax
MAINTENANCE MANUAL LINE
Points of Inspection
Interval Operating hours Chapter
Reference
Signa-
ture
* no periodic maintenance (re-
quirement after the first 25 hours
of operation)
25* 50 100 200 400 600 1000
7) Oil change
Drain oil from oil tank.
X X
(4
X 12–20–00
Oil change
Check the oil tank and clean the oil
tank if contaminated.
X
(4
X 12–20–00
Oil change,
Cleaning the
oil tank
Refill oil tank with approx. 3 liters of
oil. For oil quality, see Operators
Manual (OM) latest edition.
X X
(4
X 12–20–00
Purging the
oil system
Inspect and clean screen in turbo oil
sump.
X
(4
X 12–20–00
Turbo sump
screen
Install new oil filter
X X
(4
X 12–20–00
Oil filter
change
(4
use of leaded fuel (AVGAS) more than 30% of operation
8) Fuel system
Inspect the fuel system on the en-
gine side for leaks.
X 12–20–00
Fuel system
Inspect the fuel system for damages.
X
9) Engine management
Check the ECU and its mountings.
X 12–20–00
Checking
ECU
In case of faults or warnings read out
the ECU fault memory (fault and da-
ta logs).
X X 12–20–00
Read out
the ECU da-
ta memory
10) FUSE BOX
Check the FUSE BOX and its
mounting.
X
Visual inspection of the fuses.
X X
Effectivity: 916 i A / C24
Edition 0/Rev. 1
05–20–00
Page 11
December 01 2023