3
Two stage cooling capability with independent circuits and control.
High performance copper tube / aluminum plate (RTPF) fin condenser and evaporator coils with optional coating.
EER’s up to 12.0
IEER’s up to 13.2 with single speed indoor fan motor and 13.8 with 2-speed/VFD indoor fan motor system
Gas heating efficiencies up to 81% thermal efficiency.
Dedicated vertical and horizontal air flow duct configuration models. No field kits required.
Utility connections through the side or bottom. Bottom connections are also in an enclosed environment to help prevent water
entry. Field supplied couplings are required.
Scroll compressors on all units. This makes service, stocking parts, replacement, and trouble-shooting easier.
Precision sized TXV metering device on each refrigerant circuit.
Easy-adjust, belt-drive motor available. Motor assembly also contains a fan belt break protection system on all models and reli-
able pillow block bearing system that allows lubrication thru front of the unit.
Single-point gas/electrical connection.
Sloped, composite drain pan sheds water; and won’t rust.
Standardized controls and control box layout. Standardized components and controls make stocking parts and service easier.
Clean, large, easy to use control box.
Color-coded wiring.
Large, laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy.
Single, central terminal board for test and wiring connections.
Fast-access, handled, panels for easy access on normally accessed service panels.
“No-strip” screw system guides screws into the panel and captures them tightly without stripping the screw, the panel, or the unit.
Mechanical cooling (125°F to 35°F/52°C to –2°C) standard on all models. Low ambient controller allows operation down to
–20°F/–29°C
Redundant gas valve for 2-stage gas heating capacity control with induced-draft flue exhaust design to help ensure no flue gas can
escape into the indoor air stream.
Exclusive IGC solid state gas controller for on board diagnostics with LED error code designation, burner control logic and
energy saving indoor fan motor delay.
2-in. (51mm) disposable filters on all units, with 4-in. (102 mm) filter track field-installed.
Refrigerant filter-drier on each circuit.
High and low pressure switches. Added reliability with high pressure switch and low pressure switch.
Many factory-installed options ranging from air management economizers, 2 position dampers, manual outdoor air dampers, plus
convenience outlets, disconnect switch and smoke detectors.
Factory-installed Perfect Humidity™ dehumidification system.
Standard Parts Warranty: 10 year aluminized heat exchanger, 5 year compressor, 1 year others.
Optional 2-Speed Indoor Fan Motor System utilizes a Variable Frequency Drive (VFD) to automatically adjust the indoor fan
motor speed between cooling stages. Available on 2-stage cooling models 17-28 with electromechanical controls or RTU Open.
FEATURES/BENEFITS

Other manuals for Bryant 581J series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant 581J series and is the answer not in the manual?

Bryant 581J series Specifications

General IconGeneral
BrandBryant
Model581J series
CategoryAir Conditioner
LanguageEnglish

Related product manuals