FAN AND MOTOR SPECIFICATIONS
Table 7 — Fan and Motor Specifications
HIGH WALL
UNIT SIZE
12K 6K 9K 12K 18K 24K 30K 36K
(115 V) (208/230 V) (208/230 V) (208/230 V) (208/230 V) (208/230 V) (208/230 V) (208/230 V)
HIGH WALL FAN
Material
Acrylontrile
Styrene
+30%GF
Acrylontrile
Styrene +30%GF
Acrylontrile
Styrene +30%GF
Acrylontrile
Styrene +30%GF
Acrylontrile
Styrene
+30%GF
Acrylontrile
Styrene
+30%GF
Acrylontrile
Styrene
+30%GF
Acrylontrile
Styrene
+30%GF
Type GL-98*638-IN GL-98*638-IN GL-98*638-IN GL-98*638-IN GL-98*758-IN GL-121*883-IN GL-121*883-IN GL-121*883-IN
Diameter In (mm) 3.86(98) 3.86(98) 3.86(98) 3.86(98) 3.86(98) 4.76(121) 4.76(121) 4.76(121)
Height In (mm) 25.12(638) 25.12(638) 25.12(638) 25.12(638) 29.84(758) 34.76(883) 34.76(883) 34.76(883)
HIGH WALL FAN MOTOR
Model ZKFP-20-8-113 ZKFP-20-8-6-21 ZKFP-20-8-6-21 ZKFP-20-8-6-21 ZKFP-30-8-3-10 ZKFP-58-8-1-6 ZKFP-58-8-1-6 ZKFP-58-8-1-6
Volts V 115 208/230 208/230 208/230 208/230 208/230 208/230 208/230
Phase 1 1111 1 1 1
FLA 0.2 0.25 0.25 0.25 0.13 0.5 0.5 0.5
MCA 0.25 0.31 0.31 0.31 0.16 0.63 0.63 0.63
Type DC
Insulation
class
EEEEEE EE
Safe class
IP20(Welling,
Dayang)/ IPX0
(Tongda)
IPX0 IPX0 IPX0 IPX4
IP20(Welling)/
IP40(Dayang)
IP20(Welling)/
IP40(Dayang)
IP20(Welling)/
IP40(Dayang)
Input W
65.8
(Welling,Tongda)/
68 (Dayang)
24.6 24.6 36 36
113.5(Welling)/
125(Dayang)
113.5(Welling)/
125(Dayang)
113.5(Welling)/
125(Dayang)
Output W 20 20 20 20 30 58 58 58
Range of
current
Amps
0.467±10%
(Welling,Tongda)/
0.486±10%
(Dayang)
0.182±10% 0.182±10% 0.182±10% 0.11±10%
0.364±10%
(Welling)/0.4±10%
(Dayang)
0.364±10%
(Welling)/0.4±10%
(Dayang)
0.364±10%
(Welling)/0.4±10%
(Dayang)
Rated
current
Amps
0.467
(Welling,Tongda)/
0.486 (Dayang)
0.182 0.182 0.182 0.11
0.364(Welling)/
0.4(Dayang)
0.364(Welling)/
0.4(Dayang)
0.364(Welling)/
0.4(Dayang)
Capacitor µF NA NA NA NA NA NA NA NA
Rated HP HP 0.027 0.027 0.027 0.027 0.04 0.077 0.077 0.077
Speed rev/min 1200/910/720 1100/850/700 1100/850/700 1050/930/870 1240/1024/916 1000/850/700 1050/880/630 1050/880/630
Rated RPM rev/min 1200 1100 1100 1050 1240 1000 1050 1050
Max. input W 65.8 24.6 24.6 24.6 36 113.5 113.5 113.5