38 Specifications subject to change without notice. SM619PHA-03
Eb (Communication error between the Indoor PCB and Display Board)
Description: Indoor PCB does not receive feedback from the display board.
Recommended parts to prepare:
Wiring mistake
PCB faulty
Display board malfunction
Troubleshooting and Repair:
Is it still displaying
the error code ?
The unit operates normally.NO
Check the wirings and
connection.
YES
Is it normal?
Correct the connection
or replace the wirings.
NO
Replace the indoor main PCB.
YES
Is the problem solved?
Replace the display board.NO
The unit operates normally.
YES
Power o. Wait 2 minutes
then restart.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bryant 619PHA Series and is the answer not in the manual?