—4—
PRODUCT DATA INFORMATION
PHYSICAL CHARACTERISTICS
Builder’s/Standard Programmable Models:
Dimensions: See drawing
Appearance: Plastic, designer white, textured, white rubber push buttons
Non-Programmable/Programmable Models:
Dimensions: See drawing
Appearance: Plastic, eggshell color, textured
ELECTRICAL CHARACTERISTICS
Builder’s/Standard Programmable Models:
Input Volts/Amps: 24vac, 1 VA
Non-Programmable/Programmable Models:
Input Volts/Amps: 24vac, 5 VA
ENVIRONMENTAL REQUIREMENTS:
Operating Temperature/Relative Humidity: 32°F (0°C) to 104°F (40°C), 95% rh non-condensing
Storage Temperature/Relative Humidity: –40°F (–40°C) to 134°F (56°C), 95% rh non-condensing
PROGRAM SPECIFICATIONS:
Builder’s/Standard Programmable Models:
Temperature set point range: 50°F (10°C) to 90°F (32°C)
Manual changeover
Non-volatile memory
Fahrenheit or Celsius selectable
Power-stealing option on AC model
Selectable fan ON or OFF with auxiliary heating (HP model)
Five-minute compressor timeguard
Four cycles per hour maximum
Auxiliary heat LED on heat pump models
Non-Programmable Models:
Temperature set point range: 40°F (4°C) to 90°F (32°C)
Separate heat and cool set points
Auto changeover—can be disabled
Clean filter reminder: installer adjustable
Permanent memory
Equipment On indicator
Programmable Models:
Temperature set point range: 40°F (4°C) to 90°F (32°C)
Separate heat and cool set points
Auto changeover—can be disabled
Clean filter reminder: installer adjustable
Permanent memory
Programming days: 7 day
Programming periods: 4—Wake, Day, Eve, Sleep
Hold function
Copy previous day function
Humidity display and control (Thermidistat Control only)
Equipment On indicator (Thermidistat Control only)
WIRING REQUIREMENTS:
Power: 24vac nominal, 18- to 30-vac, 50/60 Hz
Wiring: Standard thermostat wire 18 to 22 gage.