11
PERFORMANCE DATA
EFFICIENCY
UNIT SIZE 036040 036060 036080 048080 060100 060120
CAPACITY* Direct Vent (2---pipe)
(Shaded capacities are specified on
the rating plate)
Upflow 38000 56000 75000 75000 94000 113000
Downflow 38000 56000 75000 75000 94000 113000
Horizontal 38000 56000 74000 75000 93000 112000
CAPACITY* Non---Direct vent (1---pipe)
Upflow 38000 56000 75000 75000 94000 113000
Downflow 38000 56000 74000 75000 93000 112000
Horizontal 38000 56000 74000 75000 93000 112000
AFUE* Direct Vent (2---pipe)
N o n --- w e a t h e r i z e d IC S
Upflow 95 93
Downflow 93.6 91.5
Horizontal 94.4 92.3
A F U E * N o n --- D i r e c t Ve n t ( 1 --- p i p e )
Non-weatherized ICS
Upflow 94.7 92.4
Downflow 93.3 91.4
Horizontal 94.1 91.4
Input Btuh {
40000 60000 80000 80000 100000 120000
UNIT SIZE 036040 036060 036080 048080 060100 060120
CERTIFIED TEMPERATURE RANGE ---
_F(_C)
20---50
( 1 1 --- 2 8 )
30---60
( 1 7 --- 3 3 )
40---70
( 2 2 --- 3 9 )
30---60
( 1 7 --- 3 3 )
30---60
( 1 7 --- 3 3 )
40---70
( 2 2 --- 3 9 )
CERTIFIED EX STATIC PRESSURE
(in. wc)
Heating 0.10 0.12 0.15 0.15 0.20 0.20
Cooling 0.50 0.50 0.50 0.50 0.50 0.50
AIRFLOW (CFM)}
Heating 845 1040 1180 1450 1890 2065
Cooling 1260 1250 1240 1620 1635 1925
*Capacity and AFUE in accordance with U.S. Government DOE test procedures.
{Gas input ratings are certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft. (610 M), reduce ratings 2% for each 1000 ft. (305 M) abovesea
level. In Canada, derate the unit 5% for elevations 2000 to 4500 ft. (610 to 1372 M) above sea level.
}Airflow shown is for bottom only return---air supply with factory supplied 3/4 ---in. (19 mm) washable filter(s).
For air delivery above 1800 CFM, see Air Delivery table for other options.
An airflow reduction of up to 7% may occur when using the factory---specified 4 5/16---in. (110 mm) wide, high efficiency media filter.
For best furnace efficiency when using the 4---5/16---in. (110 mm) wide media filter, adjust the blower speed tap to near the mid---point of the rise range.
ICS --- Isolated Combustion System.