1
Product Data
PLUS 95st MODEL 355CAV
DELUXE 4--WAY MULTIPOISE VARIABLE--SPEED
MULTI--STAGE CONDENSING GAS FURNACE
Series 100 Input Rates: 60,000 thru 120,000 Btuh
A05085
Building on our industry-- leading family of condensing furnaces,
the Plus 95st, model 355CAV with the consistent comfort that is
provided by Bryant’s PerfectSenset feature is our greatest
advancement to date.
In fact, temperature and humidity control, operating efficiency,
installation flexibility (and simplicity), and quiet operation are all
evidence of Bryant’s ingenuity.
The PerfectSense feature provides up to 73% more consistent
temperature control than single stage furnaces. This comfort is
achieved through Bryant’s modulating operation, and the many
patented features found in our PerfectSense control. This control
senses the heating needs of the home, and interacts with the
mulit--stage gas valve, a variable--speed inducer motor, and
variable--speed blower motor, allowing the Plus 95s to adjust
combustion air, firing rate, and airflow to maintain peak ef ficiency
and exceptional comfort throughout the operating cycle.
These important components also contribute to exceptionally quiet
operation as well, especially when the Plus 95s operates in it’s
lowest stage of heating operation. Inducer motor and blower motor
operation and gas consumption all adjust to their lowest and
quietest levels. This quiet operation can be enjoyed the majority of
the year, as the Plus 95s can operate as frequently as 83% of the
time during heating operation.
The Plus 95s also achieves heating efficiencies of 95 percent
Annual Fuel Utilization Efficiency (AFUE) in the upflow
configuration. The Plus 95s provides the ultimate in electrical
efficiency as well, due to the tried and true patented Everlastict
secondary heat exchanger, and it’s industry--leading low air-- side
pressure drop.
This ultra-- highly efficient 4-- way multipoise gas furnace is not
only flexible in terms of how it can be installed, but is as easy to
install as any Bryant condensing furnace equipped with the
Evolutiont solution, as compared to other, more complicated
modulating furnaces from other manufacturers.
Bryant Evolution System—When this Plus 95s gas furnace is
matched with the Evolution Control and an air conditioner or heat
pump, homeowners will experience the ultimate in PerfectSense
and Perfect Humidity features through unmatched control of
temperature, humidity, indoor air quality, and zoning. The Bryant
Evolution System also allows for worry--free operation through
on--screen, text--based service reminders and equipment
malfunction alerts.
For even greater comfort and convenience, match the Plus 95s
furnace with a two--speed Puron air conditioner or heat pump
(Bryant’ s Hybrid Heatt dual fuel system!) This will create a fully
communicating system, requiring only 4 thermostat wires between
system components, and some troubleshooting can even be done
from the outdoor unit without entering the home. Optional remote
access through telephone or Internet is also available when
combined with a remote connectivity kit.
Question and Answer IconNeed help?

Do you have a question about the Bryant PLUS 95S and is the answer not in the manual?

Bryant PLUS 95S Specifications

General IconGeneral
Blower MotorVariable-speed
Gas ValveTwo-stage
Fuel TypeNatural Gas
Heating Capacity40, 000 to 120, 000 BTU/h
Warranty10-year parts limited warranty upon registration
Efficiency Rating95% AFUE

Summary

Product Data and Key Features

Advanced Comfort and Efficiency

Highlights PerfectSense, temperature/humidity control, and quiet operation for enhanced comfort.

System Integration and Compatibility

Details integration with Bryant Evolution System and Hybrid Heat compatibility.

Detailed Feature Breakdown

Intelligent Comfort Controls

Covers PerfectSense/Perfect Humidity control, SmartEvap, and Fan On Plus features.

Heat Exchanger and Ignition Technology

Explains Three-Pass Primary, Flow-Through Secondary heat exchangers, and Perfect Light Igniter.

Furnace Component Identification

Physical and Performance Data Summary

Performance Ratings and Capacities

Details AFUE, airflow, capacity (BTUH), and temperature rise ranges.

Airflow and Static Pressure Charts

CFM Delivery vs. External Static Pressure

Comprehensive table of airflow volumes (CFM) at various external static pressures.

Venting System Requirements

Electrical Specifications and Wiring Diagrams

Typical Furnace Wiring Schematic

Illustrates typical wiring connections for thermostats, condensing units, and power supply.

Vent Pipe Length Limitations (Direct Vent)

Maximum Allowable Pipe Lengths by Altitude

Tables specifying maximum direct vent pipe lengths based on altitude and number of elbows.

Vent Pipe Length and Insulation Guidelines

Extended Vent Pipe Lengths and Altitude Factors

Continues tables for direct vent pipe lengths, considering altitude and elbow counts.

Installation Clearances and Orientation

Minimum Clearances to Combustibles

Specifies required minimum clearances from furnace to combustible materials.

Guide Specifications Summary

System Description and Quality Assurance Standards

Overviews system type, design standards, certifications, and testing procedures.

Equipment Component Specifications

Details specifications for blower motor, heat exchangers, controls, and casing materials.