Diode Tester
Range
Accuracy
Test
Current
(Typical)
Open
Circuit
Voltage
2.0000V
1%+1d
0.4mA
< 3.5 VDC
Capacitance
RANGE
Accuracy*
50.00nF
0.8% + 3d
500.0nF
0.8% + 3d
5.000
F
1.5% + 3d
50.00
F
2.5% + 3d
500.0
F**
3.5% + 5d
5.000mF**
5.0% + 5d
25.00mF**
6.5% + 5d
*Accuracies with film capacitor or better
**In manual-ranging mode, measurements
not specified below
45.0
F/0.450mF/4.50mF (450 counts) for
500.0
F/5.000mF/25.00mF ranges
respectively
DC Loop Current %4~20mA
4mA = 0% (zero); 20mA = 100% (span)
Resolution: 0.01% Accuracy: 25d
DC Current
RANGE
Accuracy
Burden
Voltage
500.00
A
0.15%+20d
0.15mV/
A
5000.0
A
0.1%+20d
0.15mV/
A
50.000mA
0.15%+20d
3.3mV/mA
500.00mA
0.15%+30d
3.3mV/mA
5.0000A
0.5%+20d
45mV/A
10.000A*
0.5%+20d
45mV/A
*10A continuous, >10A to 20A for 30 second
max with 5 minutes cool down interval
AC, DC
AC
& AC+DC
AC
Current
RANGE
869s
867s
Burden
Voltage
Accuracy
DC, 50Hz ~ 60Hz
500.00
A
0.5% +
50d
1.0% +
40d
0.15mV/
A
5000.0
A
0.15mV/
A
50.000mA
3.3mV/mA
500.00mA
3.3mV/mA
5.0000A
45mV/A
10.000A*
45mV/A
40Hz ~ 1kHz
500.00
A
0.7% +
50d
1.0% +
40d
0.15mV/
A
5000.0
A
0.15mV/
A
50.000mA
3.3mV/mA
500.00mA
3.3mV/mA
5.0000A
45mV/A
10.000A*
45mV/A
1kHz ~ 20kHz
500.00
A
2.0% +
50d
Unspec'
d
0.15mV/
A
5000.0
A
0.15mV/
A
50.000mA
3.3mV/mA
500.00mA
3.3mV/mA
5.0000A
10.000A*
Unspec'
d
Unspec'
d
45mV/A
20kHz ~ 100kHz
500.00
A
5.0% +
50d
Unspec'
d
0.15mV/
A
5000.0
A
0.15mV/
A
50.000mA
3.3mV/mA
500.00mA
3.3mV/mA
5.0000A
10.000A*
Unspec'
d
Unspec'
d
45mV/A
*10A continuous, >10A to 20A for 30 second
max with 5 minutes cool down interval