EasyManua.ls Logo

Brymen BM869s - Hz Line Level Frequency; Hz Logic Level Frequency; Duty Cycle; T1-T2 Type-K Temperature

Default Icon
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
~ Hz Line Level Frequency
AC
Function
RANGE
Sensitivity
(Sine RMS)
Range
500mV
100mV
10Hz ~ 200kHz
5V
0.6V
10Hz ~ 100kHz
50V
6V
10Hz ~ 100kHz
500V
50V
10Hz ~ 100kHz
1000V
500V
10Hz ~ 10kHz
VFD 5V
0.5V ~ 2V*
10Hz ~ 440Hz
VFD 50V
5V ~ 20V*
10Hz ~ 440Hz
VFD 500V
50V ~ 200V*
10Hz ~ 440Hz
500
A
50
A
10Hz ~ 10kHz
5000
A
500
A
10Hz ~ 10kHz
50mA
5mA
10Hz ~ 10kHz
500mA
50mA
10Hz ~ 10kHz
5A
1A
10Hz ~ 3kHz
10A
10A
10Hz ~ 3kHz
Accuracy: 0.02%+4d
*VFD sensitivity linearly decreases from
10% F.S. @ 200Hz to 40% F.S. @ 440Hz
Hz Logic Level Frequency
RANGE
Accuracy
5.000Hz ~
1.0000MHz
0.002%+4d
Sensitivity: 2.5Vp square wave
%Duty Cycle
RANGE
Accuracy
0.1% ~ 99.99%
3d/kHz+2d
Input Frequency: 5Hz -- 500 kHz, 5V Logic
Family
T1-T2 Type-K Temperature (Model 869s
only)
RANGE
Accuracy
-50.0
C to 1000.0
C
0.3%+1.5
C
-58.0
F to 1832.0
F
0.3%+3.0
F
Type-K thermocouple range & accuracy not
included