EasyManua.ls Logo

BST ekr 500 Plus User Manual

Default Icon
21 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Web Guiding System
ekr 500 Plus
with CLS Pro 600
Translation of the
Original Quick Reference Guide
Quick Reference Guide EDV no.: MD.341.01.01
ekr 500 Plus with CLS Pro 600 Issue Date: 31.03.2009
Question and Answer IconNeed help?

Do you have a question about the BST ekr 500 Plus and is the answer not in the manual?

BST ekr 500 Plus Specifications

General IconGeneral
BrandBST
Modelekr 500 Plus
CategoryController
LanguageEnglish

Summary

General Information

System Overview

Describes the assembly and commissioning of the web guiding system ekr 500 Plus with CLS Pro 600.

Used Terms

Defines the relationship between selection buttons and sensors for guiding mode.

Start-up ekr 500 Plus

Set DIL Switches

Details on setting DIL switches (S4.4 to S4.8) for actuator and servo-center selection.

Start-up of the EMS Actuator

Guides the initial setup and configuration of the EMS actuator components.

Determine Sense of Motor Rotation

Checks the assignment of arrow keys to actuating direction (motor rotation) of the actuator.

Determine Guiding Direction

Setting guiding direction for line or contrast guiding on the CLS Pro 600 sensor.

Actuator without Position Feed Back

Specific setup procedures for actuators lacking position feedback.

Adjust Gain of Servo-center Component (OMG 4, OMG 8)

Procedure for adjusting the gain of servo-center components for stable guiding operation.

Actuator with Position Feed Back

Specific setup procedures for actuators with position feedback.

Determine Guiding Direction for Operating Mode Servo-center

Checks guiding direction for servo-center mode with position feedback actuators.

Adjust Stroke Limitation and Servo-center Position

Adjusts software limit switches and servo-center position using a special setup menu.

Setting up the CLS Pro 600

General

Explains the display area colors indicating different operating modes (AUTOMATIC, MANUAL, SETUP, Error).

Requirements

Specifies controller mode (MAN) and correct sensor-to-material distance for setup.

Adjust Password Level

Procedure to log in as Administrator to access sensor setup and configuration parameters.

Configuration

Teaches the sensor's mounting position via a 4-step procedure, starting with manual positioning.

Material Setup

At the Controller

Instructions on switching the controller to MAN operating mode via the controller keyboard.

At the Sensor

Procedure for selecting MAN operating mode on the sensor using arrow keys and ENTER.

Edge Set-up Mode

Guides through setting up the sensor for edge detection, involving positioning and confirmation.

Line Setup Mode

Guides through setting up the sensor for line detection, involving positioning and confirmation.

Optimise Gain

Related product manuals