Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 24- 63
Electronic card – 5710
Warning codes with registration
Mast reach/retraction control, joystick R12
1. Check that R12 is located in its bracket.
- Check that the voltage across R12 (yellow and grey cable) is 7-
7.5 VDC.
- Check that there is no play or oxidisation on the connector pins
on terminal X11.
- The voltage on input 504 should be 3.7 +/-0.6 VDC when R11 is
correctly adjusted.
2. If the correct voltage is on input 504 and the fault remains, re-
place the A5 electronic card.
Code 92
Description Potentiometer R12 for mast reach in/out movement
gives incorrect voltage (<0.3 or >7.0
V)
Error mode General error
Error cause 1. Faulty potentiometer/wiring or activated input with-
out connected potentiometer
2. Defective electronic card A5
Comments
https://www.forkliftpdfmanuals.com/