Valid from serial number T-code
713962- 403-414, 669-671, 716-718
Order number Date
218920-040 2005-06-01
© BT Europe AB Service Manual REFLEX RR B/E, RR B/E CC 24- 95
Electronic card – 5710
Error Codes
Pump motor, M3
1. Check that the motor cables 5, 6 and 7 are intact and connect-
ed correctly.
2. If the cables are okay, replace A2.
Code 228
Description Too high current on lift regulator
Error mode Lift regulator error
Error cause 1. Motor cables incorrectly connected
2. Defective lift regulator, A2
Comments
https://www.forkliftpdfmanuals.com/