Conversion instructions Logano GA124 special gas-fired boiler • Issue 2012/10
We reserve the right to make any changes due to technical modifications.
Conversion to propane3
3 Conversion to propane
Read the instructions before conversion for your
safety.
The following instructions must be followed for
conversion of the boiler to propane:
1. If the boiler was in operation, close the gas shut-off
valve. Otherwise continue with step 3.
2. Disconnect system from the power supply and set
the thermostat to the lowest setting.
3. Remove safety screws from the left and right side
panels, then lift the front panel of the boiler and pull
it forward.
WARNING!
RISK TO LIFE
due to not observing the attached
conversion instructions.
If you wish to convert the boiler for
operation with propane, the conversion
from natural gas to propane must be
carried out first as specified by the
attached conversion instructions.
Fig. 1 Removing front panel of boiler