OPERATING INSTRUCTIONS
Operating Instructions
reCovery Mode:
IN THE EVENT THAT A DOWNLOADER GOES INTO RECOVERY MODE TAKE THE FOLLOWING STEPS TO
RECOVER.
1. Press “Y” to recover
2. If an error code is displayed unplug the downloader, wait ten seconds, and then plug it back in.
3. Once the downloader has been plugged back in it will again display a promt to enter recovery mode, press “Y.”
4. Downloader will recover wehicle by returning it to stock.
5. Once vehicle reaches stock the downloading process can safely be restarted.
PyroMeTer CalIbraTIon ProCedure
BEFORE THIS STEP CAN BE COMPLETED, COMPLETELY INSTALL THE OUTLOOK AND ALL OF ITS COMPONENTS.
1. Vehicle must be set to Stock HP/TQ levels-meaning no HP/TQ modications of any kind (downloader or plug-in
modules).
2. Engine must be put under full load for as long as possible on the hottest day possible. It is suggested to drive up
a hill or pull a trailer.
3. During a heavy load pull, record the highest reading.
4. Take that reading and add 150° to the high number and that will be your new de-fuel number that you do not
want to exceed.
Important: These steps are performed when using the Outlook Monitor.