EasyManua.ls Logo

Bunn ITB/ITCB - BREW CYCLE AND STARTUP ISSUES

Bunn ITB/ITCB
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 31
TROUBLESHOOTING (cont.)
PROBABLE CAUSE REMEDY
PROBLEM
Check plumbing and shut-off
valves
Check for voltage across the termi-
nals at the terminal block.
Test the ON/OFF switch. Refer
to the test switch procedures on
page 50.
Test the BREW switch. Refer to the
test switch procedures on page
50.
Test the brew valve. Refer to the test
outputs procedures on page 48.
Substitute a control board known
to be in good working order.
1. No water
2. No power or incorrect voltage to
the brewer
3. ON/OFF switch
4. Brew switch
5. Brew valve
6. Control Board
Brew cycle will not start
41581.2 091609

Table of Contents

Related product manuals