Bunn-O-Matic Corporation
5
Electrical Install
Anelectricianmustprovideelectricalserviceasspeciedinconformancewithalllocal,state,and
federal electrical codes.
The ITCB is a dual voltage unit. There is a voltage switch located on the back of the brewer. The
brewer is wired from the factory with a 2-wire+ground power cord and plug rated for 120VAC at
15amps.For208VACor240VACcongurations,the3-wire+groundpowercordmustbeordered
fromBUNN:P/N:01699.0000.Thetechnicianmustsupplya20amprated,4-wireplug.
For 120V brewers:
Step 1: Plugbrewerintothepowersource.
For 120/208VAC or 120/240VAC brewers:
Step 1: Remove the rear panel.
Step 2: Disconnect the 2-wire+ground cord from the terminal block.
Step 3: Feed the 3-wire+ground power cord through the strain relief.
Step 4: Attach the wire ends to the terminal block.
Step 5: Attach the ground wire to connector below the terminal block.
Step 6: Check that all connections are tight.
Step 7:Placethedualvoltagetoggleswitchinthecorrectposition.
Step 8: Tighten the strain relief and replace the rear panel.
Step 9:Plugtheunitintothepowersource.
Initial Start-Up
Step1:PlacethemainpowerswitchintotheOnposition.
WhenthemachineisturnedonandtheEnableBrewOn/Offswitchispressed,itwillbegintollthetank.
Afterthetankllsthemachinewillautomaticallybegintheheatingcycle.Thiswilltakeapproximately20minutes.
Once the water temperature has reached the programmed Brew Lockout temperature it will display the ready screen.
The machine will continue to heat until it reaches its programmed shut-off temperature.
READY TO BREW
WATER TEMP: 205º