Bunn-O-Matic Corporation
9
Thisfunctionallowstheoperatortoadjustthesensitivityoftherellcircuit.Thisis
mainly a troubleshooting feature. Water in different geographical locations can have
differentconductivities.Byadjustingthesensitivityoftherellcircuit,thiswillallowthe
brewer to operate under various water conditions.
Thisfunctionallowstheoperatortovieworentertheactualowratecomingoutofeach
sprayhead.ThisisNotusedtocontroltheactualowrate,buttotelltheinternalproces-
sorhowfastthewaterisowing.
Thisfunctionallowstheoperatortoviewortoentertheactualowratecomingoutof
thedilutionnozzle.Thisisnotusedtocontroltheactualowrate,buttotelltheinternal
processorhowfastthewaterisowing.
Thisfunctionallowstheoperatortotestandentertheactualowrateofthe
sprayhead(s) and the bypass/dilution for each side of the brewer by dispensing each
separately for one minute. The volumes are then entered into the brewer.
This function allows the operator to track the total number of brew cycles completed, as
well as the number of batches brewed using each of the brew buttons. There are (up to)
three resettable counters, and one life counter that is not resettable.
This function allows the operator to set separate temperatures for each selected recipe.
This function allows the operator to enter the machine’s asset number. This can be use-
ful for tracking the usage or service of an individual machine within a group.
This function allows the operator to enter in the telephone number to call if service is
needed. The service number will be displayed anytime there is a fault message dis-
played.
(ForAuthorizedServicePersonelOnly)
This function allows the testing of individual components and the ability to check
switches for proper function. This function also tests the funnel sensor coil’s frequency
(diagnostic tool for troubleshooting purposes only).
Refer to Service Manual for in depth procedures.
This function allows the operator to erase all of the previously entered recipes and ad
messages. Factory-set default values will replace All previous settings.
XX REFILL XXX
(-) (+)DONE
SPRAY OZ/M: XX.X
(-) (+)DONE
DILUTE OZ/M: XX.X
(-) (+)DONE
CALIBRATE FLOW?
NO YES
BREW COUNTERS?
NO YES
SET RECIPES TEMPS
NO YES
ENTER ASSET #
NO YES
ENTER SERVICE #
NO YES
SERVICE TOOLS
NO YES
FACTORY DEFAULTS
NO YES