22
TROUBLESHOOTING (cont.)
Dispenser Locked Out
Dispense stations not working.
Cooling system failure.
Dispense station not working
All stations dispense concentrate
only
1. Check Dispense Lockout switch.
1. Refrigeration or cold water recir-
culation system.
1. Dispense Lockout switch set to
OFF position.
2. Dispense switch failed
Main water supply
Frozen bath
Inlet water valve failed
(A) Set switch to ON position.
(B) Check switch and harness for
proper continuity.
Check all previous items that pre-
tain to refrigeration or cold water
recirculation
Place switch in ON position.
Check switch and harness for proper
continuity.
Check for ON position.
A) Compressor relay/contacts
shorted - replace relay.
B) Recirculating pump - replace or
check for kinked flex line.
A) Check for 120V or 230V power
when dispensing. If yes, replace
valve. If no, check harness for
proper continuity. Then replace
circuit board if needed.
PROBLEM
PROBABLE CAUSE
REMEDY
54261.0001 090817

Related product manuals