TROUBLESHOOTING (cont.)
Troubleshooting ProceduresPossible Cause
Screen Displayed
TO CANCEL
PRESS ON/OFF
TO FINISH:
PRESS BREW
BREW STOPPED!
SERVER REMOVED?
1. Soft Heat Server was moved out
of position after the brew cycle was
started.
1. ON/OFF switch was pressed after
the brew cycle was started.
1. Tank Heater failure
2. Triac Failure
3. Control Board/Thermistor failure
To resume brewing, correctly
position the Soft Heat Server and
press BREW again. The brew cycle
resumes from the point it was inter-
rupted.
OR
Press ON/OFF to terminate the brew
cycle.
TO CANCEL
PRESS ON/OFF
TO FINISH:
PRESS BREW
BREW STOPPED!
IS SWITCH OFF?
To resume brewing, press BREW
again. The brew cycle resumes form
the point it was interrupted.
OR
Press ON/OFF to terminate the brew
cycle.
Service Required
Service Required
Service Required
CHECK HEATING
CIRCUIT
HEATING TIME
TOO LONG
34025.1 082404