EasyManua.ls Logo

Burkert 3360 Series User Manual

Burkert 3360 Series
160 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operating Instructions
Type 3360, 3361,
AE3360, AE3361
Electromotive control valve

Table of Contents

Other manuals for Burkert 3360 Series

Questions and Answers:

Burkert 3360 Series Specifications

General IconGeneral
BrandBurkert
Model3360 Series
CategoryControl Unit
LanguageEnglish

Summary

OPERATING INSTRUCTIONS

Symbols

Explains warning and information symbols used in the manual.

Definition of terms

Clarifies key terms and abbreviations used in the document.

INTENDED USE

Defines the proper applications and limitations of the control valve.

BASIC SAFETY INSTRUCTIONS

Outlines essential safety precautions for installation, operation, and maintenance.

GENERAL NOTES

Provides contact information, warranty details, and internet resources.

PRODUCT DESCRIPTION

General description

Provides an overview of the electromotive control valve's functionality and features.

Properties

Lists key characteristics and advantages of the valve and actuator system.

Variants

Details different types and configurations of the control valve available.

STRUCTURE AND FUNCTION

Representation – Structure of the electromotive control valve

Illustrates the physical components and layout of the control valve.

Valve position after supply voltage failure

Explains how the valve behaves during power interruptions.

Safety position

Describes how to configure and manage the valve's safe state during failures.

Display of the device status

Details how the LED ring indicates device status and valve position.

CONTROL ELECTRONICS

Interfaces

Outlines the electrical input, output, and communication interfaces of the control electronics.

Functional diagram of the electromotive control valve

Functionality of the control electronics

Schematic presentation of the position control

Schematic presentation of the process control

Energy storage SAFEPOS energy-pack (option)

TECHNICAL DATA

Conformity

States compliance with relevant EU directives.

Standards

Lists applied standards for conformity demonstration.

Approvals

Mentions product listing and references for UL environments.

Type label

Explains the information provided on the device's type label.

Operating conditions

Specifies environmental and operational limits for device use.

Derating pressure and temperature ranges

Lists derating values for operating pressure based on medium temperature.

General technical data

Provides dimensions, weight, materials, and connection types.

Electrical data

Details electrical specifications, connection types, and safety class.

Flow rate values and flow rate characteristics for angle seat control valve (Type 3360)

Flow rate values and flow rate characteristic for seat size 15

Presents flow data and characteristic curves for seat size 15.

Flow rate values and flow rate characteristic for seat size 20

Presents flow data and characteristic curves for seat size 20.

Flow rate values and flow rate characteristic for seat size 25

Presents flow data and characteristic curves for seat size 25.

Flow rate values and flow rate characteristic for seat size 32

Presents flow data and characteristic curves for seat size 32.

Flow rate values and flow rate characteristic for seat size 40

Presents flow data and characteristic curves for seat size 40.

Flow rate values and flow rate characteristic for seat size 50

Presents flow data and characteristic curves for seat size 50.

Flow rate values and flow rate characteristics for globe control valve (Type 3361)

Flow rate characteristics

Describes flow characteristics for globe control valves based on seat size.

Flow values

Provides Kv values for globe control valves across different seat sizes and strokes.

INSTALLING THE VALVE

Safety instructions

Highlights critical safety warnings for valve installation procedures.

Installation of devices with threaded connection, flange connection or clamp connection

Details the installation process for specific connection types.

Installation of devices with welded connections

Remove actuator from the valve body

Installing actuator on valve body

ELECTRICAL INSTALLATION

Electrical installation with circular plug-in connector

Details the process for connecting the valve using circular plug-in connectors.

X3 – M12 circular plug, 4-pin or 5-pin, operating voltage and büS/CANopen communication

Electrical connection Fieldbus gateway

Electrical installation with cable gland

Connecting the cable

START-UP

Safety instructions

Critical safety warnings related to operating personnel and improper device startup.

Base settings for position control

Details the factory default and sequence for configuring position control base settings.

Base settings for process control

Details the factory default and sequence for configuring process control base settings.

Set safety position

Adjustment of position controller – execute X.TUNE

Set standard signal for set-point position

Select physical unit for process control

Configure process values

Scaling the process control

Set dead band for process control

Setting up process control and executing P.LIN, P.TUNE

Adjusting process control (P.TUNE)

Set AUTOMATIC operating state

OPERATION

Overview: Availability of the operating elements

Lists available operating elements and their functions based on device variants.

Display elements

LED illuminated ring

Explains the function and modes of the LED illuminated ring for status indication.

Set LED operation mode

Operating elements

DIP switch

Explains the function of each DIP switch for device configuration.

OPEN button and CLOSE button

Describes the function of OPEN and CLOSE buttons for manual valve operation.

Mechanical manual override

büS service interface

SIM card – acquire and save data (option)

DISPLAY OPERATION (OPTION)

User interface

Introduces the touchscreen display and its navigation elements.

Display views

Configuration view

Detailed views

Description of symbols

Access rights and password protection

BASIC FUNCTIONS

Changing the operating state, AUTOMATIC, MANUAL

Explains how to switch between AUTOMATIC and MANUAL operating states.

Enable – disable sealing function

Enabling – disabling correction characteristic

Change effective direction

Disabling process control

MANUAL OVERRIDE OF VALVE

Electrical override of valve on devices without a display module

Describes electrical manual override using buttons on devices without a display.

Electrical override of valve on devices with a display module

Electrically actuating the valve using the Bürkert Communicator or display

Actuating the valve mechanically

Remove blind cover or display module

Actuating the valve mechanically

Mounting the fieldbus gateway on the actuator

OPERATING STRUCTURE AND FACTORY SETTING

Operating structure of the configuration area

Illustrates the menu structure for the configuration area.

Position controller maintenance

Position controller diagnostics

Operating structure – 2-a, “Inputs/outputs” configuration area

Operating structure – 2-b, “Inputs/outputs” configuration area

Operating structure – 3, Industrial communication

Operating structure – 3-a, “Process controller” configuration area

Operating structure – 3-b, process controller maintenance

Operating structure – 4-a, “Display” configuration area

Operating structure – 5-a, configuration area “General settings”

Operating structure – 5-b, configuration area “General settings”

Operating structure – 5-d, general settings maintenance

Context menu for operation on display

INDUSTRIAL ETHERNET

Fieldbus gateway description

Introduces the fieldbus gateway and its connection ports.

Access to büS service interface

Explains how to access the büS service interface within the fieldbus gateway.

LEDs for indicating network connection status

Technical data Industrial Ethernet

PROFINET IO specifications

Lists technical specifications for PROFINET IO communication.

EtherNet/IP specifications

Lists technical specifications for EtherNet/IP communication.

Projecting via fieldbus

Setting the Ethernet parameters for EtherNet/IP, PROFINET, Modbus TCP

Web server

Connecting to the web server

Instructions for connecting to the device's web server for configuration.

Configuring Ethernet participants

Device Status NAMUR NE 107

büS Control Object

CANopen

Projecting via fieldbus

Guides on obtaining EDS files for CANopen fieldbus projection.

büS

Cabling of büS networks

Points to additional information for cabling büS networks.

MAINTENANCE

Safety instructions

Crucial safety warnings for performing maintenance tasks.

Wearing parts of the valve

Identifies common wearing parts of the valve that may require replacement.

Visual inspection

TROUBLESHOOTING AND MESSAGES

Error notifications

Lists common error notifications, their descriptions, device behavior, and corrective measures.

Notifications on device status “Out of specification”

Notifications on device status “Function check”

ACCESSORIES, REPLACEMENT PARTS

Communication software

Introduces the Bürkert Communicator software for device communication.

büS service interface

Describes the büS service interface for PC communication.

Spare parts

Spare parts for control valves of Types 3360 and 3361

Lists spare parts for SAFEPOS, display modules, seals, and spindle guides.

Spare parts for globe control valve Type 3361

Assembly tools

DISASSEMBLY

Safety instructions

Critical safety warnings for device disassembly, covering pressure and electrical hazards.

PACKAGING AND TRANSPORT

STORAGE

DISPOSAL

Related product manuals