Instruction Manual PANDA WV 0250-2000 C_EN_en 21 / 24
The machine runs too hot. Ambient temperature too
high.
Observe the permitted
ambient temperature, see
Technical Data [22].
Temperature of the process
gases at the inlet too high.
Observe the permitted
gas inlet temperature, see
Technical Data [22].
Oil level too low. Top up oil.
The backing pump is not
correctly defined.
Contact Busch.
The oil is black. Oil change intervals are too
long.
Drain the oil and fill in
new oil, see Oil Change
[16].
The machine runs too hot. See problem "The ma-
chine runs too hot".
For the solution of problems not mentioned in the troubleshooting chart contact your
Busch representative.