Storage | 4
Instruction Manual PANDA WV 0250-2000 C_EN_en 7 / 24
4 Storage
Seal all apertures with adhesive tape or reuse provided caps.
If the machine is to be stored for more than 3 months:
Wrap the machine in a corrosion inhibiting film.
Store the machine indoors, dry, dust free and if possible in original packaging
preferably at temperatures between -20 ... 55 °C.
5 Installation
5.1 Installation Conditions
NOTICE
Use of the machine outside of the permitted installation conditions.
Risk of premature failure!
Loss of efficiency!
Take care that the installation conditions are fully complied with.
Make sure that the environment of the machine is not potentially explosive.
Make sure that the ambient conditions comply with the Technical Data [22].
Make sure to use a suitable backing pump, if necessary seek advice from your Busch
representative
Make sure that the environmental conditions comply with the protection class of the
motor and the electrical instruments.
Make sure that the installation space or location is vented such that sufficient cooling
of the machine is provided.
Make sure that cooling air inlets and outlets are not covered or obstructed and that
the cooling air flow is not affected adversely in any other way.
Make sure that the oil sight glass (OSG) remains easily visible.
Make sure that enough space remains for maintenance work.
Make sure that the machine is placed or mounted horizontally, a maximum of 1° in
any direction is acceptable.
Make sure that the machine is secured either from the four feet or from the discharge
flange.
Check the oil level, see Oil Level Inspection [15].
Make sure that all provided covers, guards, hoods, etc. are mounted.
If the machine is installed at an altitude greater than 1000 meters above sea level:
Contact your Busch representative, the motor should be derated or the ambient
temperature limited.