8 Overhaul
WARNING
Machines contaminated with hazardous material.
Risk of poisoning!
Risk of infection!
If the machine is contaminated with hazardous material:
Wear appropriate personal protective equipment.
NOTICE
Improper assembly.
Risk of premature failure!
Loss of efficiency!
It is highly recommended that any dismantling of the machine that goes beyond any-
thing that is described in this manual should be done through Busch.
In case of the machine having conveyed gas that was contaminated with foreign materi-
als which are dangerous to health:
Decontaminate the machine as much as possible and state the contamination
status in a ‘Declaration of Contamination’.
Busch will only accept machines that come with a completely filled in and legally binding
signed ‘Declaration of Contamination’ (form downloadable from
www.buschvacuum.com).
9 Decommissioning
Shut down the machine and lock against inadvertent start up.
Vent the connected lines to atmospheric pressure.
Version with water-oil heat exchanger:
Turn off the water supply.
Disconnect the water supply.
Open the water bypass valve (WBV).
Blow through the water cooling inlet with compressed air.
Disconnect all connections.
If the machine is going to be stored:
See Storage [10].
9.1 Dismantling and Disposal
Drain the oil.
Remove the exhaust filters.
Remove the oil filter.
Separate special waste from the machine.
Dispose of special waste in compliance with applicable regulations.