5 | Installation
14 / 36 0870201428_RA0165-0305D_O2_-0004_IM_en
5.4 Fitting the Coupling
E
L
Coupling hub (machine side) Coupling hub (motor side)Coupling sleeve
Radial screw
Max. admissible
torque: 10 Nm
Machine type Coupling size Value “E” (mm) Value “L” (mm)
RA 0165 D
BoWex
®
M-48 4 104
RA 0205 D
RA 0255 D
RA 0305 D
In case of a machine delivery without motor:
Fit the second coupling hub on the motor shaft (separately delivered).
Axially adjust the sleeve in such a way until value "E" (or “L”) is reached.
When the coupling adjustment is done, lock the coupling hub by tightening the
radial screw.
Mount the motor on the machine by including the coupling sleeve.
For further coupling information, go to www.ktr.com and download the instruction
manual of the BoWex
®
coupling.
5.5 Electrical Connection
DANGER
Live wires.
Risk of electrical shock.
Electrical installation work must only be executed by qualified personnel.
NOTE
The operation with variable speed, i.e. with a variable-frequency drive or a soft starter
unit, is allowed as long as the motor is admitted and the permitted motor speed range is
neither underrun nor exceeded (see Technical Data [30]).
Seek advice from your Busch representative.
Make sure that the power supply for the motor is compatible with the data on the
nameplate of the motor.
The electrical installation must comply with applicable national and international
standards.