15
EN
Trained person:
Has received instruction and studied the informati
-
on in this document concerning the tasks entrusted
to him/her, and the possible risks in the event of
inappropriate behaviour.
Skilled personnel:
Based on the professional training received, know
-
ledge and experience, and knowledge of the
relevant definitions, is qualified to install the product,
to commission and to service it.
11. Technical Data
AQA nano
Connection nominal diameter DN 25
Connection thread outside thread 1"
Limescale protection up to max. 20°dH m
3
/h max. 1.5
l/min. max. 25
l/min. min. 0.6
Limescale protection capacity m
3
max. 110 ± 10*
months max. 12
Operating pressure PN bar 16
Temperature water inflow max. °C 30
Temperature environment max. °C 40
Temperature boiler max. °C 80
Dimensions of device & connection dimensions:
Width x height mm 300 × 710
Fitting length (with screw connections) mm 234
Clearance: Wall middle of pipe mm 80 to 100
Weight kg ca. 11
Cable length mm 1000
Mains connection Volt/Hertz 230/50, 110/60 **
Electrical connected rating Watt 5.5
Capacity stand-by operation Watt 1.8
Energy consumption per m
3
water kWh 0.018
Type of protection IP 54
* depending on water quality ** country-specific