How to get water from BWT WS755 Water Dispenser?
- EErin GordonSep 2, 2025
Open the mains stop valve, and open the inlet and outlet valves to the water softener.
How to get water from BWT WS755 Water Dispenser?
Open the mains stop valve, and open the inlet and outlet valves to the water softener.
Why is water running from the drain constantly in my BWT Water Dispenser?
If the unit is in recharge mode, this is normal; wait until the recharge is complete. If the unit is not in recharge mode, isolate the softener and call for service.
What to do if water level in brine cabinet of BWT WS755 Water Dispenser reaches overflow?
First, verify that the line pressure is within the water softener's specifications by connecting a pressure gauge to a water outlet; the pressure should be between 1.7 and 5.0 bar. If the pressure falls outside this range, fit a pressure reducing valve or booster pump as needed. Also, check that the drain line isn't kinked, blocked, or frozen and that the power is on with secure connections.
What to do if the electronic display of my BWT Water Dispenser shows an error?
If the electronic display shows an error, check that all the connections are secure, then turn the power back on and allow the system to reset. If the display shows the error code "SALt" and an audible alarm sounds, fill the brine cabinet with salt. Pressing the SET key will reset the salt alarm to the full capacity of salt. Also, ensure the power is on and all connections are secure.
How to fix BWT Water Dispenser that regenerates at the wrong time?
If your BWT Water Dispenser regenerates at the wrong time, reset the present time.
What to do if BWT WS755 shows error code and audible alarm sounds?
If the BWT Water Dispenser's display shows error code "Err 1" and an audible alarm sounds, ensure all connections are secure. Turn the power off for 10 seconds, then turn it back on to allow the system to reset. If the display shows error code "SALt" and an audible alarm sounds, fill the brine cabinet with salt. Pressing the SET key will reset the salt alarm to the full capacity of salt. Also, verify that the power is on and all connections are secure.
How to reset regeneration time on BWT WS755 Water Dispenser?
To correct the regeneration time, reset the present time and then reset the regeneration time.
Covers electrical safety, correct application, child safety, and temperature protection.
Advice on site selection, space, weight, and access for installation and maintenance.
Guide to setting the current time and inputting the measured water hardness level.
Procedure to define the automatic regeneration cycle's daily timing.
Resolving hard water issues by checking salt levels and power connections.
Troubleshooting steps for ensuring the softener is online and hardness settings are correct.
Diagnosing and resolving issues with no water supply or constant drain flow.
Addressing excessive salt usage, display errors, and incorrect regeneration timing.
Covers electrical safety, correct application, child safety, and temperature protection.
Advice on site selection, space, weight, and access for installation and maintenance.
Guide to setting the current time and inputting the measured water hardness level.
Procedure to define the automatic regeneration cycle's daily timing.
Resolving hard water issues by checking salt levels and power connections.
Troubleshooting steps for ensuring the softener is online and hardness settings are correct.
Diagnosing and resolving issues with no water supply or constant drain flow.
Addressing excessive salt usage, display errors, and incorrect regeneration timing.
| Brand | BWT |
|---|---|
| Model | WS755 |
| Category | Water Dispenser |
| Language | English |
Loading...