Generator/ Transmitter: Tracing the Direct Connected Signal
The tracing technique used to follow the Generator/
Transmitter signal when applied by a direct connection
method (Direct Connection Leads, Signal Clamp or Signal
Injector) is almost exactly the same as the normal tracing
technique used on Power, Radio or
All
Scan Modes but with
the following differences:
The signal that the Locator is detecting will get weaker
the further away from the Generator/ Transmitter that
you go. It will be necessary to regularly adjust (increase)
the Locator Sensitivity Control to compensate for this.
MXT2 Transmitter only:
Having traced the signal for a short distance it may be
worthwhile switching the MXT2 Transmitter to the
alternative frequencies to see if they give a stronger
response. Choose the frequency that gives the strongest
response and continue with the trace.
NOTE It is not possible to search for the signal above any leads connecting the Generator/ Transmitter
to the service or above the Earth Lead connected to the Earth Stake.