23
KIWI Plus is an aerosoltherapy device operating with new generation MESH technology. The principle of
nebulisation on which it is based, combines, in a single device, the best features of compressor technology (rapid and
effective nebulisation of any type of drug) and ultrasonic technology (absolute silence and dual power supply, mains
or battery), making it ideal for any type of use on adults and children, both in home-care and in emergency, while
travelling or outdoors. All this in addition to construction/operational features developed in the design phase and
unique to this type of equipment. The drug containment and nebulisation chamber is made of PC (polycarbonate), a
material that ensures high resistance. Over 200 minutes of autonomy with internal rechargeable Lithium-Iones battery
and the special design of the nebulisation chamber ensures maximum therapeutic efficacy, reducing the amount of
non-spray composition drug to less than 0.1 ml (the lowest declared on the market). The mesh technology in this
product has been optimized to the higher level, making possible to achieve particularly high and effective nebulization
parameters with 93% breathable fraction and an MMAD of 1.51 μm
CAUTION
CONSULT THE USER MANUAL BEFORE USING THE DEVICE
ALWAYS FOLLOW YOUR DOCTOR'S INSTRUCTIONS WHEN ADMINISTERING THE DRUG
NEVER DISASSEMBLE THE DEVICE. FOR ANY INTERVENTION CONTACT THE DISTRIBUTOR
AND/OR CA-MI TECHNICAL ASSISTANCE
REMOVE THE DEVICE FROM THE CARRYING CASE BEFORE EACH USE
GENERAL WARNINGS
16. When opening the package, check the integrity of the device and the power supply. Pay particular attention to
any damage to the plastic parts, which may expose live inner parts, and to breaks and/or peeling of the power
supply and relative power cable. In such cases, do not connect the plug to the power socket. Always carry
out these checks before each use.
17. Before connecting the device, always check that the electrical data indicated on the power supply data label and
the type of plug used, match those of the mains electric power supply to which it is to be connected.
18. Follow the safety regulations for electrical equipment and in particular:
- Exclusively use original Accessories and Spare parts supplied by Manufacturer. Only use original power
supplies of the type indicated in this manual.
- DO NOT THROW DEVICE IN THE FIRE OR PLACE NEAR FLAMES OR HEAT SOURCES. THE
DEVICE MAY EXPLODE.
- Never immerse the device and power supply in water;
- Put the device on a flat and stable surface in order to avoid accidental falls or overheating the device or
power supply;
- Do not use the device in environments where there are anaesthetic mixtures inflammable with air, oxygen or
nitrous oxide;
- Do not use the device in anaesthesia and pulmonary ventilation systems
- Do not touch the device with wet hands and always prevent the device from coming into contact with liquids;
- The use of this device by children and/or physically or mentally impaired people always requires the careful
supervision of an adult with full mental faculties;
- Do not leave the device on and/or connected to the power socket when it is not used;