9
POINT CHECK FUNCTION
Press LED on the remote controller three times and then press SWING three times within 10 seconds, the buzzer rings for 2 seconds and the
air conditioner enters the information enquiry status.
Next, press LED to search the information. Press SWING to search the remaining information. When the air conditioner enters the enquiry
information status, it displays the code name in 2 seconds (see Table 3).
Table 3—Point Check Function
Enquiry Information Displaying Code Meaning
T1 T1 T1 temp.
T2 T2 T2 temp.
T3 T3 T3 temp.
T4 T4 T4 temp.
T2B Tb T2B temp.
TP TP TP temp.
TH TH TH temp.
Targeted Frequency FT Targeted Frequency
Actual Frequency Fr Actual Frequency
Indoor fan speed IF Indoor fan speed
Outdoor fan speed OF Outdoor fan speed
EXV opening angle LA EXV opening angle
Compressor continuous running time CT Compressor continuous running time
Causes of compressor stop ST Causes of compressor stop
Reserve A0
Reserve A1
Reserve b0
Reserve b1
Reserve b2
Reserve b3
Reserve b4
Reserve b5
Reserve b6
Reserve dL
Reserve Ac
Reserve Uo
Reserve Td