the pellets ow (auger) there could exist minimum differences in the material used, in roughness and porosity,
which could generate usual variations in fuel transportation (pellets), causing a ame raising or drapping with
a possible switching off at lower powers.
Depending on the type of pellets it could be necessary a parameters adjustment, please contact an
Authorized Assistance Service.
11
INSTALLATION
11.1 INTRODUCTION
The assembly position must be chosen depending on environment, outlet, chimney ue.
Check with local authorities if there are any restrictive regulations which regard the combustible air inlet,
room ventilation, fume exhaust system together with chimney ue and chimney pot.
Check if there is the combustible air inlet.
Check the probable presence of other stoves or appliances which could depress the room.
Check at switched on stove if there is the presence of CO in the room.
Check if the chimney has the necessary draught.
Check if during the fume passage all has been executed in safety (probable fume losses and distances from
ammable materials, etc.…).
The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and chimney
ue cleaning.
The installation must enable en easy access to the electric connection plug (see ELECTRIC CONNECTION
page 22).
To install more appliances, the external air inlet must be correctly dimensioned (see FEATURES page 44).
11.2 OVERALL DIMENSIONS
Fig. 14 - General dimensions: Vega / Trend
LEGEND Fig. 14 page 14
1 54 cm
2 105 cm

Table of Contents