the pellets ow (auger) there could exist minimum differences in the material used, in roughness and porosity,
which could generate usual variations in fuel transportation (pellets), causing a ame raising or drapping with
a possible switching off at lower powers.
• Depending on the type of pellets it could be necessary a parameters adjustment, please contact an
Authorized Assistance Service.
11
INSTALLATION
11.1 INTRODUCTION
• The assembly position must be chosen depending on environment, outlet, chimney ue.
• Check with local authorities if there are any restrictive regulations which regard the combustible air inlet,
room ventilation, fume exhaust system together with chimney ue and chimney pot.
• Check if there is the combustible air inlet.
• Check the probable presence of other stoves or appliances which could depress the room.
• Check at switched on stove if there is the presence of CO in the room.
• Check if the chimney has the necessary draught.
• Check if during the fume passage all has been executed in safety (probable fume losses and distances from
ammable materials, etc.…).
• The installation of the appliance must enable an easy access for appliance, fume exhaust pipes and chimney
ue cleaning.
• The installation must enable en easy access to the electric connection plug (see ELECTRIC CONNECTION
page 22).
• To install more appliances, the external air inlet must be correctly dimensioned (see FEATURES page 44).
11.2 OVERALL DIMENSIONS
Fig. 14 - General dimensions: Vega / Trend
LEGEND Fig. 14 page 14
1 54 cm
2 105 cm