18NM 40/20 - Operating Instructions
15
Minimum cross-sectional area of conductors
Área mínima de sección transversal de los
conductores.
Tab. 1 TAB 1IEC 60335-1
mm
2
a
Rated current of appliance A
Corriente nominal A
Nominal cross-sectional area
Área transversal nominal
>0,2
>3
>6
>10
>16
>25
>32
>40
0,5
a
0,75
1,0
1,5
2,5
4
6
10
≤3
≤6
≤10
≤16
≤25
≤32
≤40
≤63
÷
÷
÷
÷
÷
÷
÷
÷
These cords may only be used if their length does not exceed 2 m between the
point where the cord or cord guard enters the appliance and the entry to the plug.
Estos cables solo se pueden usar si su longitud no supera los 2 m entre el punto
donde el cable o la protección del cable entran en el aparato y la entrada al
enchufe