EasyManua.ls Logo

Calpeda NMS - User Manual

Calpeda NMS
88 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
(CAD979BHF=:I;<9ACBC;=F5BH=ACBC6@C77C
@CG97CID@9879BHF=:I;5@G=B;@9GH5;9DIADG
=BGHI:=;9#F9=G9@DIAD9B=B@C7?65IK9=G9
(CAD9G79BHF=:I;9GVIB\H5;9ACBC6@C7
CA65GACBC6@C779BHF=:I;57CBIBGC@CFC89H9
%CBC6@C7?9BGH9;G79BHF=:I;5@DIAD
@CG97CID@9879BHF=:I;55@DCAD9B
(CADMC8’FC8?CK9>98BCK=FB=?CK9>98BCGHCDB=CK9
¤¿½¿²Ë¸¼¹µÁÅijϺµ½ÃÀµÁº»µ¹ÂÿÐÃÐq¿Ä±½Ã»ÎµÁ
åÓÌÓ·ÎÓ˜Ì˚ ˆÂÌÚÓ·ÂÊÌ˚ ̇ÒÓÒ˚
单级直联离心泵
! ! &! ! &
&'%(-"!"%!#%c(&" (5;=B5 !H5@=5BC
"#%'!!&'%('"!& (5;9 B;@=G<
'%&!'(! +9=H9  9IHG7<
!&'%('"!&#"(%c('&'"!
(5;9  F5B[5=G
!&'%("!&(&" (U;=B5  GD5dC@
%'!&''"!&!)&!!%
+=85B  +J9BG?5
!!&)""%&%' (5;=B5  &989F@5B8G
!&'%((t,'"*! +HFCB5  (C@G?=
Á¸º·¼¹Ä ȹ¼Ã¼Ä¿ÁÆ ªµ»Î´±  •»»·½¹ºË
àÌÒÚÛ͈ËË ÔÓ ˝ÍÒÔÎÛ‡Ú‡ˆËË
ëÚ. 65
êÛÒÒÍËÈ
使用说明书
页码  中文
!+,&%3983%0+37CB;5@@(5;=B5

Table of Contents

Other manuals for Calpeda NMS

Questions and Answers

  • M
    Mrs. Kelly BallAug 10, 2025
    Why Calpeda Water Pump engine does not start?
    • S
      Sandra Price DVMAug 10, 2025
      If your Calpeda Water Pump engine isn't starting, several factors could be at play. First, confirm that the mains frequency and voltage are appropriate. Next, ensure the power supply cable is correctly connected and that the thermal overload protection is properly set. Also, verify that the pump shaft turns freely and that the thermal overload protection isn't causing the issue. Finally, check for blown or defective fuses, and if found, replace them, re-examining the power supply and shaft movement.
  • Z
    zsandersAug 15, 2025
    How to increase flow in Calpeda Water Pump?
    • M
      Mark ManningAug 15, 2025
      If your Calpeda Water Pump isn't delivering enough flow, several factors could be responsible. Ensure that the pipes and accessories you're using are appropriately sized for the application. Clean the impeller to remove any deposits or solid bodies, and consider installing a suction filter. If the rotor is deteriorated or worn, along with the pump case, replacement is necessary. For water with dissolved gases, use the feeder gate to perform opening and closing maneuvers. If the liquid's viscosity is too high, the pump may be unsuitable. Finally, check and correct the direction of rotation by inverting the electrical connections on the terminal board.
  • R
    randallwelchAug 20, 2025
    Why is my Calpeda Water Pump making noise and vibrating?
    • J
      Joshua WardAug 20, 2025
      If your Calpeda Water Pump is making unusual noises or vibrating, worn bearings could be the cause, requiring replacement. Another potential reason is an unbalanced power supply, so it's important to verify that the mains voltage is correct.
  • T
    thomas92Aug 26, 2025
    What to do if my Calpeda Water Pump is blocked?
    • K
      kristierandallAug 26, 2025
      If your Calpeda Water Pump is blocked, it could be due to a few reasons. If the pump hasn't been used for a while, try unblocking it by using a screwdriver to turn the notch on the back of the shaft. Also, check for any solid objects in the impeller and remove them. In some cases, the bearings might be blocked, which would mean they need to be replaced.
  • R
    Ruben WattsAug 30, 2025
    Why is my Calpeda Water Pump leaking from the mechanical seal?
    • P
      potterdavidAug 30, 2025
      If your Calpeda Water Pump is leaking from the mechanical seal, several factors could be the cause. Ensure the pump casing is full of liquid and all air has been removed, especially if the seal ran dry or got stuck. If abrasive particles have scored the seal, install a suction filter and use a seal designed for the liquid you're pumping. If the seal isn't right for your application, choose one that is. A slight drip during filling or the first start-up might occur as the seal adjusts; wait to see if it stops. If leaking continues, check the points above.
  • C
    Carrie BarnesSep 4, 2025
    What to do if Calpeda Water Pump functions but no water comes out?
    • K
      Kyle JacksonSep 4, 2025
      If your Calpeda Water Pump is running but not pumping water, it could be due to air in the pump or suction pipe; release the air using the delivery control valve. Air infiltration is another possibility; check for and seal any loose connections. Also, the foot valve might be blocked or the suction pipe not fully submerged; clean or replace the valve and ensure the pipe is properly placed. Lastly, a blocked suction filter could be the issue; clean or replace it, and also check for solid bodies in the impeller.

Calpeda NMS Specifications

General IconGeneral
Insulation classF
Pump casingCast iron
Inlet/Outlet SizeVaries by model
TypeCentrifugal
ApplicationsWater supply, irrigation, industrial uses
Liquid temperatureUp to 40°C
Ambient temperatureUp to 40°C
MotorSingle-phase or three-phase
Frequency50 Hz
ImpellerBrass, Stainless steel
ShaftStainless steel
Max Flow Rate160 m³/h
PowerVaries by model
MaterialCast iron, Stainless steel