EasyManua.ls Logo

Calspas patio plus - Spa Jets and Pumps; Jet Operation and Pump Controls; Circulation vs. Two-Speed Pump

Default Icon
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2017 Portable Spa
LTR20171001, Rev. C
Preparing for Your New Portable Spa
www.calspas.com
16
If you have tried priming the pump several
times unsuccessfully using the control panel,
you can bleed the air from the pump manually.
1. Shut off the power to the spa.
2. Using a Phillips screwdriver, remove the
front panel from the spa and locate the
pump.
3. Close the gate valve on the discharge side
of the pump (if your spa is installed with
one.)
4. Turn the bleeder valve counter clockwise
with a small pair of pliers until the air has
been released from the pump.
5. If this is unsuccessful, loosen the union nut
on side of the pump with channel locks.
When air is bled out, tighten the nut.
6. Turn on power to the spa and press the
JETS button. If there is still air trapped in
the pump, repeat steps 2 through 5 until
the pump primes.
Bleeding Air from the Pump