EasyManua.ls Logo

Cambium Networks Force 425 - Force 4525 L Mounting Instructions

Cambium Networks Force 425
171 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 2: System Hardware
151
Where:
Is:
a
the surface area in square meters
V
wind speed in meters per second
Force (in pounds) = 0.0042Av
2
Where:
Is:
A
the surface area in square feet
v
wind speed in miles per hour
Applying these formulae to the ePMP device at different wind speeds, the resulting wind loadings are
shown in Table 116 and Table 117.
Table 116 Force 4525L wind loading (Kg)
TypeofePMPdevice
Largest surfacearea(squaremeters)
Wind speed (meters per second)
30
40
50
Force 4525L Integrated
0.03
2.82 Kg
5.02 Kg
7.84 Kg
Table
117
Force 4525L wind loading (lb)
TypeofePMPdevice
Largest surfacearea(squarefeet)
Wind speed (miles per hour)
80
100
120
Force 4525L Integrated
0.28
7.53 lb
11.76 lb
16.93 lb
Force 4525L mounting instructions

Table of Contents