To rename inputs:
Press and hold the relevant input select button. Letters in the name are selected by turning the volume
knob.
To access the conguration menu:
Press and hold the Mode button. These are the menu options:
Clip detector on/o
LCD brightness (o/dim/bright)
Input gain trim menu access
Volume ramp on/o
Volume display: -84 to 0 dB or 0 to 72 units
Fixed input gain menu access
To adjust the gain of an input:
Press the button next to INP TRIM
Select the input required
Use volume knob to set gain between 0 and -12 dB
(the available range is restricted if the volume is set very low)
Press Mode button to return to volume display
To set up xed input gain
Press the button next to FIXED INP
Select the input required
Set the xed gain using the volume control.
(the OFF setting does not disable the input- it leaves the input gain
subject to the volume control)
Press Mode button to return to volume display
To access the service menu:
Hold in the Mode button when mains power is switched on. These are the menu options:
Speaker short detection on/o
DC oset detect on/o
XD system on/o
Counter access
Press Mode button to return to volume display
The counter page keeps a total of the number of times these events have occurred:
Clipping detected CL
DC oset detected DC
Overload protection OV
Overtemperature shutdown TM
Speaker short detected SH
Time on in hours ON
Press Mode button to return to service menu
To reprogram the PICs:
Hold in the ON/standby button when mains power is switched on. The word DOWNLOAD appears on
the LCD.
60