AUTOMATIC DOOR RELEASE function
> 5s
This function allows you to automatically open the entrance when you ring the bell from the entry
panel. Communication is not activated and the call ends automatically. It is recommended for
professional practices.
The function is available by default. It can be removed during system programming.
Press and hold the
button for more than 5 seconds to activate or deactivate the function.
The LED switches on to indicate that the function is active.
Porter functions
These functions are only available where there is a porter’s desk.
Call notifi cation from the porter
If the porter wishes to be called back, the LED turns on.
The LED turns o when communication with the porter
starts.
Request for call to porter
Press the button to let the porter know that you want to be
called back.
Alarm contact
When the alarm contact is activated, an emergency signal is
sent directly to the porter’s desk.
The video receiver will beep intermittently to signal
activation.