p. 25 - Manual FA01443-EN - 01/2020 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Opening speed
Set the opening speed (percentage of maximum speed).
Configuration
Gate travel settings
Opening speed 40% to 100% (Default 100%)
Closing speed
Sets the closing speed (percentage of maximum speed).
Configuration
Gate travel settings
Closing speed 40% to 100% (Default 100%)
Opening slowdown speed
Set the slowdown speed during opening (as a percentage of the maximum speed).
Configuration
Gate travel settings
Opening slowdown speed 15% to 60% (Default 50%)
Closing slowdown speed
Set the slowdown speed during closing (as a percentage of the maximum speed).
Configuration
Gate travel settings
Closing slowdown speed 15% to 60% (Default 50%)
Travel sensitivity
Adjust the obstruction detection sensitivity during boom travel.
Configuration
Gate travel settings
Travel AST control Deactivated (Default)
Minimum
Average
Maximum
Customised
Slowdown sensitivity
Adjust the obstacle-detection sensitivity level during slowdown.
Configuration
Gate travel settings
Slowdown AST control Deactivated (Default)
Minimum
Average
Maximum
Customised
Soft start
Set a slowdown of a few seconds after each opening and closing command.
Configuration
Gate travel settings
Soft start Deactivated (Default)
On
Partial opening point
Determine the gate partial opening point, as a percentage of total travel.
Configuration
Gate travel settings
Part. open point 10% to 100% (20% Default)