p. 9 - Manual FA01443-EN - 01/2020 - © CAME S.p.A. - The contents of this manual may be changed at any time and without notice. - Translation of the original instructions
Technical data
MODELS BKV15AGS BKV20AGS BKV25AGS BKV15RGS BKV20RGS
Power supply (V - 50/60 Hz) 230 AC 230 AC 230 AC 120 AC 120 AC
Motor power supply (V) 36 DC 36 DC 36 DC 36 DC 36 DC
Board power supply (V) 26 DC 26 DC 26 DC 26 DC 26 DC
Standby consumption (W) 14 14 14 14 14
Standby consumption with the RGP1 (W)
module
0,8 0,8 0,8 0,8 0,8
Power (W) 200 250 300 200 250
Transformer thermal protection (°C) 120 120 120 120 120
Current draw (mA) 8 9 10 8 9
Maximum current draw (mA) 20 20 20 20 20
Colour RAL 7024 RAL 7024 RAL 7024 RAL 7024 RAL 7024
Operating temperature (°C) -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55
Thrust (N) 800 900 1000 800 900
Maximum thrust (N) 1200 1350 1500 1200 1350
Maximum operating speed (m/min) 12 12 12 12 12
Operating time (s) 180 180 180 180 180
Cycles/hour CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
Protection rating (IP) 54 54 54 54 54
Insulation class I IIII
Reduction ratio (i) 40 40 40 40 40
Weight (kg) 20 21 21 20 21
MODELS BKV15AGE BKV20AGE BKV25AGE BKV15ALS BKV20ALS BKV25ALS
Power supply (V - 50/60 Hz) 230 AC 230 AC 230 AC 230 AC 230 AC 230 AC
Motor power supply (V) 36 DC 36 DC 36 DC 36 DC 36 DC 36 DC
Board power supply (V) 26 DC 26 DC 26 DC 26 DC 26 DC 26 DC
Standby consumption (W) 14 14 14 14 14 14
Standby consumption with the RGP1
(W) module
0,8 0,8 0,8 0,8 0,8 0,8
Power (W) 200 250 300 200 250 300
Transformer thermal protection (°C) 120 120 120 120 120 120
Current draw (mA) 8 9 10 8 9 10
Maximum current draw (mA) 20 20 20 20 20 20
Colour RAL 7024 RAL 7024 RAL 7024 RAL 7040 RAL 7040 RAL 7040
Operating temperature (°C) -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55 -20 ÷ +55
Thrust (N) 800 900 1000 800 900 1000
Maximum thrust (N) 1200 1350 1500 1200 1350 1500
Maximum operating speed (m/min) 12 12 12 12 12 12
Operating time (s) 180 180 180 180 180 180
Cycles/hour CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
CONTINUOUS
OPERATION
Protection rating (IP) 54 54 54 54 54 54
Insulation class IIIIII
Reduction ratio (i) 40 40 40 40 40 40
Weight (kg) 20 21 21 20 21 21
Fuse table
MODELS BKV15AGS BKV20AGS BKV25AGS BKV15RGS BKV20RGS
Line fuse 2 A F 2 A F 2 A F 4 A F 4 A F
Control-board fuse 630 mA F 630 mA F 630 mA F 630 mA F 630 mA F
Accessories fuse 1.6 A F 1.6 A F 1.6 A F 1.6 A F 1.6 A F
MODELS BKV15AGE BKV20AGE BKV25AGE BKV15ALS BKV20ALS BKV25ALS
Line fuse 2 A F 2 A F 2 A F 2 A F 2 A F 2 A F
Control-board fuse 630 mA F 630 mA F 630 mA F 630 mA F 630 mA F 630 mA F
Accessories fuse 1.6 A F 1.6 A F 1.6 A F 1.6 A F 1.6 A F 1.6 A F