Technical data
MODELS BXV04AGS BXV06AGS BXV08AGS BXV10AGS BXV04RGS BXV06RGS BXV08RGS BXV10RGS
Power supply (V - 50/60 Hz) 230 AC 230 AC 230 AC 230 AC 110 AC 110 AC 110 AC 110 AC
Motor power supply (V) 24 DC 24 DC 24 DC 24 DC 24 DC 24 DC 24 DC 24 DC
Standby consumption (W) 5,5 5.5 5.5 5.5 5.5 5.5 5.5 5.5
Power (W) 170 270 400 400 170 270 400 400
Maximum current draw (A) 7 11 16 16 7 11 16 16
Colour RAL 7024 RAL 7024 RAL 7024 RAL 7024 RAL 7024 RAL 7024 RAL 7024 RAL 7024
Thrust (N) 350 600 800 1000 350 600 800 1000
Maximum operating speed (m/min) 12 12 11 11 12 12 11 11
Operating time (s) 180 180 180 180 180 180 180 180
Duty cycle HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
Pinion module 44444444
Limit-switch type MECHANICAL MECHANICAL MECHANICAL MECHANICAL MECHANICAL MECHANICAL MECHANICAL MECHANICAL
Protection rating (IP) 54 54 54 54 44 44 44 44
Insulation class I I I IIIII
Average life (cycles)** 150000 150000 150000 150000 150000 150000 150000 150000
MODELS BXV06AGL BXV10AGL BXV04ALS BXV06ALS BXV08ALS BXV10ALS
Power supply (V - 50/60 Hz) 230 AC 230 AC 230 AC 230 AC 230 AC 230 AC
Motor power supply (V) 24 DC 24 DC 24 DC 24 DC 24 DC 24 DC
Standby consumption (W) 5.5 5.5 5,5 5.5 5.5 5.5
Power (W) 270 400 170 270 400 400
Maximum current draw (A) 11 16 7 11 16 16
Colour RAL 7024 RAL 7024 RAL 7040 RAL 7040 RAL 7040 RAL 7040
Thrust (N) 600 1000 350 600 800 1000
Maximum operating speed (m/min) 12 11 12 12 11 11
Operating time (s) 180 180 180 180 180 180
Duty cycle HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
HEAVY-DUTY
SERVICE
Pinion module 4 44444
Limit-switch type MAGNETIC MAGNETIC MECHANICAL MECHANICAL MECHANICAL MECHANICAL
Protection rating (IP) 54 54 54 54 54 54
Insulation class IIIIII
Average life (cycles)** 150000 150000 150000 150000 150000 150000
(*) Before installing the product, keep it at room temperature where it has previously been stored or transported at a very high or very low temperature.
(**) The average product life specified should be understood purely as an indicative estimate. It applies to normal usage conditions and where the product has been
installed and maintained in compliance with the instructions provided in the CAME technical manual. The average product life is also affected, including significantly,
by other variables such as, but not limited to, climatic and environmental conditions. The average product life should not be confused with the product warranty.
Cable types and minimum thicknesses
Cable length (m) up to 20 from 20 to 30
Power supply 230 V AC 3G x 1.5 mm2 3G x 2.5 mm2
24 V AC/DC flashing beacon 2 x 1 mm2 2 x 1 mm2
TX Photocells 2 x 0.5 mm2 2 x 0.5 mm2
RX photocells 4 x 0.5 mm2 4 x 0.5 mm2
Command and control devices * no. x 0.5 mm2 * no. x 0.5 mm2
* no. = see product assembly instructions - Warning: the cable cross-section is indicative and varies according to the motor power and cable length.
When operating at 230 V and outdoors, use H05RN-F cables compliant with 60245 IEC 57 (IEC); when indoors, use H05VV-F cables compliant with 60227 IEC 53
(IEC). For power supplies up to 48 V, use FROR 20-22 II cables compliant with standard EN 50267-2-1 (CEI).
To connect the antenna, use RG58 cable (up to 5 m).
For paired connection and CRP, use UTP CAT5 cable (up to 1,000 m).
If the cable lengths differ from those specified in the table, define the cable cross-sections according to the actual power draw of the connected devices and in
line with regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, recalculate the values in the table according to the actual power draw and distances. For information on
connecting products not covered in this manual, please see the documentation accompanying the products themselves.