EasyManua.ls Logo

CAME GARD G6000 - Troubleshooting Guide; Problem Diagnosis and Solutions

CAME GARD G6000
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
%##
,
.
28
48 '.$
28
48 '.$
,
.
%##
CAME
O
C
M
Max.
Med.
Min.
Min.
Max.
Velocità
Speed
Geschw.
Vitesse
Velocidad
Rallentamento
Deceleration
Geschw.
Ralentissement
D
Ab
e
n
c
a
el
h
e
m
ra
e
ción
2
1
3
4
5
6
7
8910
0
Rall.
Vel.
7
4
ZL 37
CONTROL PANEL
"B"
"A"
line fuse
motor fuse
accessories fuse
CAME
O
C
M
Max.
Med.
Min.
Min.
Max.
Velocità
Speed
Geschw.
Vitesse
Velocidad
Rallentamento
Deceleration
Geschw.
Ralentissement
D
Ab
e
n
c
a
el
h
e
m
ra
e
ción
2
1
3
4
5
6
7
8910
0
Rall.
Vel.
7
4
ZL 37
CONTROL PANEL
"B"
"A"
line fuse
motor fuse
accessories fuse
p. 21 - Manual FA01116 -EN - 01/2018 - © CAME S.p.A. - Translated original instructions
TROUBLESHOOTING
PROBLEM REFERENCE CHECK
The barrier neither opens nor closes 2-3-4-6-8-18 2 - Deactivate the MAINTAINED ACTION function
The boom opens but does not close 4-7-10 3 - Check the power supply and fuses
The boom closes but does not open 4-7-9 4 - The NC contacts are open
Thebarrier does not automatically close 11-12-13 6 - Deactivate the MASTER-SLAVE function
The barrier does not work with the transmitter 2-14-16 7 - Check the boom's balancing and spring tautness
The boom's direction of travel is inverted 7-18 8 - Deactivate the OBSTRUCTION DETECTION function
Only one transmitter works 22 9 - Check the opening limit-switch
The photocells do not work 12-23-24 10 - Check the closing limit-switch
The warning LED flashes quickly 4 11 - Activate the AUTOMATIC CLOSING function
The warning LED stays lit 13 12 - Check the proper direction of travel
The boom does not reach the limit-switch 7 13 - Check the control devices
The boom cannot be balanced 7-15 14 - Replace the AF card
The barrier does not slow down 7-15 15 - Check the length ration between boom and applied acces-
sories
The barrier does not work with emergency
batteries
8-25-26 16 - Memorize the radio code again
The boom starts slow 7 18 - Adjust the sensitivity
22 - Enter or duplicate the same code on all transmitters
23 - Activate the photocells
24 - Connect the photocells serially instead of in parallel fashion
25 - Check the batteries
26 - Respect the photocell's power supply polarities
Black
Red
Black
Red
Screened cable
2402C 22AWG-type cables
Connect the two control boards using terminals RX-TX-GND as shown in the fi gure.
CONTROL BOARD
SLAVE
CONTROL BOARD MASTER