Page #4 background image
450
460 240
295
225
1077
914
225
p. 4 - Manual FA01116 - EN - 01/2018 - © CAME S.p.A. - Translated original instructions
DESCRIPTION
Barrier made of painted, galvanized steel or AISI 304 stainless steel, set up to take accessories.
REQUEST EITHER LEFT OR RIGHT-HAND BARRIERS WHEN ORDERING. THE ILLUSTRATIONS IN THIS MANUAL ARE ALL FOR LEFT-
HAND BARRIERS!
INTENDED USE
This automatic barrier is designed to operate in private and public parking facilities, in residential areas or in high traffic-volume areas.
Do not install of use this device in any way, except as specified in this manual.
DIMENSIONS
TECHNICAL DATA
Model G6000 - G6001
Protection rating (IP) 54
Power supply (V - 50/60 Hz) 230 AC
Input voltage motor (V) 24 DC
Max draw (A) 15
Power (W) 300
Torque (Nm) 600
Opening time (s) 4 ÷ 8
Duty cycle INTENSIVE SERVICE
Operating temperature (°C) -20 to +55
Reduction ratio (i) 1/202
Apparatus class I
Weight (Kg) 72
OPERATING LIMITS
Model G6000 - G6001
Maximum clearance width of the passage (m) 6.5
KEY
This symbol shows which parts to read carefully.
This symbol shows which parts describe safety issues
This symbol shows which parts to tell users about.
The measurements, unless otherwise stated, are in millimeters.