8
SOUND MEANING
2 beeps (confirmation tones) system armed or disarmed
.
successful central station test or battery test
.
pulsed tone (2 seconds on, 2 seconds off) zone programmed for pulsed bell or siren is in alarm
.
continuous tone zone programmed for steady bell or siren is in alarm
circuit malfunction (trouble on supervised loops only)
.
.
.
5 beeps (error tones)
invalid function
unauthorized command attempted
error changing PIN number
wrong PIN number entered
.
.
.
zone programmed for chirping bell or siren is in alarm
.
chirping (1 second on, 4 seconds off)
zone faulted during walk-test
.
2 second beep door chime
.
continuous beeping, speeding up for last ten seconds exit delay time
.
.
continuous tone, beeping fast for last ten seconds entry delay time